Steam sterilization and Validation

Steam sterilization

Routine sterilization is a requirement for any system using a sterile filter. It is often carried out between batches or in a continuous process plant at prescribed intervals. In batch

Compressed Air Transmission and Treatment-0277

operation provided that the filter is kept pressurised and a small air bleed is allowed to flow continuously, several batches can pass before sterilization is carried out. The steam used must be saturated and free from additives or contamination, which implies its own sterile filter, see Figure 5. Steam sterilization is shown in the lower diagram of Figure 3.

A well designed system should last for 12 months before cartridge replacement is

Compressed Air Transmission and Treatment-0278

necessary; this probably means of the order of 100 sterilization cycles (according to the recommendations of the manufacturer). Typical cycles are shown in Table 1.The cost of replacement cartridges is small compared with the cost of a failure of the batch due to contamination, so replacement times should not be extended beyond 12 months.

Validation

Nothing should be left to chance when clean sterile compressed air is required for such applications as fermentation, genetic engineering, or pharmaceutical production. It is

Compressed Air Transmission and Treatment-0279

Compressed Air Transmission and Treatment-0280

essential that any filter used has been tested for integrity to ensure that it will fulfil its designed duty. The best way of testing for integrity is by a cloud of test particles in the critical rangeO.l to 0.3 micron. The test is based on creating an aerosol ofDioctyl Phthalate (DOP) in the critical particle range, challenging the filter with this and measuring any penetration with an aerosol photometer, downstream of the filter. DOP has been replaced by other substances because of possible health hazards and so corn oil or other oils are used giving the same type of particle spread when atomized. This type of validation test is carried out by the manufacturers and is not normally a procedure used by the end user

Related posts:

Case studies:Variable speed drives on golf course irrigation pumps
Concepts for estimating pumping energy costs:Systems without static head or closed loop systems
Energy and Efficiency:Theory of two level systems
ACTUATORS:PNEUMATIC-MECHANICAL SYSTEMS
VALVES:PRESSURE REGULATORS.
Material property influences:Conveying modes and Dilute phase non-suspension flow.
Conveying capability:High pressure conveying – Part IV
BASIC HYDRAULICS:USE OF HYDRAULICS
LINES, FITTINGS, AND SEALS:Tube Cutting and Deburring
Sequence valves.
Hydraulic Pumps and Pressure Regulation
Air Compressors, Air Treatment and Pressure Regulation:air receivers and compressor control
ENERGY TRANSFER BY HEAT,WORK,AND MASS:HEAT TRANSFER
GAS MIXTURES AND PSYCHROMETRICS:HUMAN COMFORT AND AIR-CONDITIONING
HEAT EXCHANGERS:THE OVERALL HEAT TRANSFER COEFFICIENT

Leave a comment

Your email address will not be published. Required fields are marked *