Air movers:Pre-cooling systems

Pre-cooling systems

In recent years, with increasing emphasis on power consumption, more consideration is being given to ways of reducing power. A European Union study has shown that 15 per cent of the world-wide energy consumption is used to produce compressed air. One proposal, with regard to reducing the power requirement for compressed air, is that the air should be cooled to -60°C before being compressed.

It was mentioned earlier, in relation to refrigeration drying of air, that units were available that were capable of cooling air to a temperature of -60°C. Such units form the basis of commercially available pre-cooling systems for compressors.

The idea is that all of the air to be compressed should be physically cooled to -60°C first. By this means the air will be extremely dry, so that there will be no need for a further dryer on the pressure side, and there will be no possibility of condensation occurring anywhere in the subsequent system. This will also eliminate the presence of water–oil emulsions that can occur in lubricated compressors.

For air at standard atmospheric pressure the density is 1.225 kg/m3 at a temperature of 15°C but at -60°C it is 1.657 kg/m3, which represents a 35 per cent increase. In terms of the volumetric flow rate it means that this is reduced to 74 per cent of the free air flow rate that would have to be compressed, and so a much smaller compressor can be used. Manufacturers of this type of system claim that up to a 30 per cent reduction in power consumption of compressors can be made by this means, and that plant maintenance is significantly reduced.

If atmospheric air at a temperature of 15°C is compressed to 2 bar gauge, the delivery temperature, assuming adiabatic compression and an isentropic efficiency of 70 per cent, will be about 165°C. For air at -60°C, similarly compressed, the delivery temperature will be about 50°C. In the first case the air would, for most applications, have to be cooled, and if it was not dried, condensation could well occur. With the pre- cooling system the air would probably not need to be cooled after being compressed, and being dry, there would be no possibility of condensation occurring.

Air movers-0091

Air movers-0092

Related posts:

Case studies:Upgrade of an oil refinery's pumping systems including installation of variable speed d...
Compressed Air Transmission and Treatment:Inducted contaminants
Particle degradation:Influence of variables
ROUBLESHOOTING HYDRAULIC SYSTEMS:ISOLATING PROBLEMS IN A HYDRAULIC CIRCUIT
FORCES IN LIQUIDS:STATIC AND DYNAMIC FACTORS.
BASIC HYDRAULICS:USE OF HYDRAULICS
Hydraulic fluid:Applications of hydraulic systems
LINES, FITTINGS, AND SEALS:Tube Cutting and Deburring
Hydraulic and Pneumatic Accessories:cost of air leaks
BASICCONCEPTS OF THE RMODYNAMICS:PROPERTIES OF A SYSTEM
PROPERTIES OF PURE SUBSTANCES:PROPERTY DIAGRAMS FOR PHASE-CHANGE PROCESSES
SUMMARY OF ENERGY TRANSFER BY HEAT,WORK,AND MASS
ENTROPY:PROPERTY DIAGRAMS INVOLVING ENTROPY
GAS MIXTURES AND PSYCHROMETRICS:P-v-T BEHAVIOR OF GAS MIXTURES: IDEAL AND REAL GASES
INTRODUCTION TO FLUID MECHANICS:VISCOSITY

Leave a comment

Your email address will not be published. Required fields are marked *