Air compressors, air treatment and pressure regulation.

Air compressors, air treatment and pressure regulation

The vast majority of pneumatic systems use compressed atmos­pheric air as the operating medium (a small number of systems use nitrogen obtained commercially from liquid gas suppliers). Unlike hydraulic systems, a pneumatic system is ‘open’; the fluid is obtained free, used and then vented back to atmosphere.

Pneumatic systems use a compressible gas; hydraulic systems an incompressible liquid, and this leads to some significant differences. The pressure of a liquid may be raised to a high level almost instan­taneously, whereas pressure rise in a gas can be distinctly leisurely. In Figure 3.1a, a reservoir of volume two cubicmetres is connected to a compressor which delivers three cubic metres of air (measured at atmospheric pressure) per minute. Using Boyle’s law (expression 1.17) the pressure rise shown in Figure 3.1b can be found.

Pressure in a hydraulic system can be quickly and easily con­ trolled by devices such as unloading and pressure regulating valves. Fluid is thus stored at atmospheric pressure and compressed to the required pressure as needed. The slow response of an air compres­sor, however, precludes such an approach in a pneumatic system and necessitates storage of compressed air at the required pressure in a receiver vessel. The volume of this vessel is chosen so there are minimal deviations in pressure arising from flow changes in loads and the compressor is then employed to replace the air used, aver­ aged over an extended period of time (e.g. a few minutes).

Deviations in air pressure are smaller, and compressor control is easier if a large receiver feeds many loads. A large number of loads

Air compressors, air treatment and pressure regulation-0053

statistically results in a more even flow of air from the receiver, also helping to maintain a steady pressure. On many sites, therefore, compressed air is produced as a central service which is distributed around the site in a similar manner to electricity, gas and water.

Behaviour of a gas subjected to changes in pressure, volume and temperature is governed by the general gas equation given earlier as expression 1.19 and reproduced here:

image

where pressures are given in absolute terms and temperatures are measured in degrees Kelvin.

A compressor increases air pressure by reducing its volume, and expression 3.1 predicts a resultant rise in temperature. A pneumatic system must therefore incorporate some method of removing this excess heat. For small systems, simple fins on the compressor (similar in construction to an air-cooled internal combustion engine) will suffice. For larger systems, a separate cooler (usually employing water as the heat-removing medium) is needed.

Atmospheric air contains water vapour, the actual amount varying from day to day according to humidity. The maximum amount of water vapour held in a given volume of air is determined by temperature, and any excess condenses out as liquid droplets (commonly experienced as condensation on cold windows). A similar effect occurs as compressed air is cooled, and if left the resultant water droplets would cause valves to jam and corrosion to form in pipes. An after cooler must therefore be followed by a water separator. Often after coolers and separators are called, collectively, primary air treatment units.

Dry cool air is stored in the receiver, with a pressure switch used to start and stop the compressor motor, maintaining the required pressure.

Ideally, air in a system has a light oil mist to reduce chances of corrosion and to lubricate moving parts in valves, cylinders and so on. This oil mist cannot be added before the receiver as the mist would form oil droplets in the receiver’s relatively still air, so the exit air from the receiver passes through a unit which provides the lubricating mist along with further filtration and water removal. This process is commonly called secondary air treatment.

Often, air in the receiver is held at a slightly higher pressure than needed to allow for pressure drops in the pipe lines. A local pressure regulation unit is then employed with the secondary air treatment close to the device using air. Composite devices called service units comprising water separation, lubricator and pressure regulation are available for direct line monitoring close to the valves and actuators of a pneumatic system.

Figure 3.2 thus represents the components used in the production of a reliable source of compressed air.

Air compressors, air treatment and pressure regulation-0054

Incoming search terms:

Related posts:

Case studies:Variable speed drives on golf course irrigation pumps
Control principles for variable speed pumping:Speed variation for positive displacement pumps
Compressed Air Transmission and Treatment:Hollow fibre filter
Compressed Air Transmission and Treatment:Inducted contaminants
Pipelines and valves:Surface finish
Particle degradation:Operating problems and Filtration problems
Multiple use systems:The use of stepped pipelines.
COMPRESSORS:Design Fundamentals
COMPRESSORS:COMMON COMPONENTS
HYDRAULIC PUMPS:Wobble Plate Inline Pumps and Bent Axis Pumps.
Control components in a hydraulic system:Pressure and temperature switches.
Servo valves.
Air treatment:Stages of air treatment,Filters,Air dryers and Lubricators.
Air Compressors, Air Treatment and Pressure Regulation:compressor types and Piston compressors
GAS MIXTURES AND PSYCHROMETRICS:HUMAN COMFORT AND AIR-CONDITIONING

Leave a comment

Your email address will not be published. Required fields are marked *