Compressed Air Transmission and Treatment:Carbon dioxide

Carbon dioxide

This is naturally present in the atmosphere in various concentrations depending on the environment and may be tolerated at much higher levels than the CO, but will impair psychomotor functions if the levels are high. It is readily removed by a variety of desiccants, both adsorptive and absorptive, with the absorptive type predominating. These materials have a limited capacity and therefore need replacing or reactivating at regular intervals.

Compressed Air Transmission and Treatment-0272

Nitrous oxide and nitrogen oxide

These are present in the air as effluents of industrial processes and by combustion within the compressor. They irritate the nasal passages and can be detected in very small concentrations. They can be removed by an appropriate grade of activated carbon or by molecular sieves.

Odours

These can be a problem, even when the compressor is correctly sized, sited and well maintained. The presence of odour is to some extent subjective and is therefore unreliable when used as the only means of monitoring for saturated elements. The most effective and common approach to odour removal is the use of activated carbon as the absorbent. These elements, as mentioned above, have a limited life, particularly when the compressed air has a significant moisture content and need replacement at intervals depending upon the concentration of vapours which they have to absorb. Compressed air which may contain trace gaseous elements such as oxides of carbon and nitrogen, methane, ethylene, ammonia, sulphur compounds, etc, cannot be effectively purified by activated carbon alone. Chemical, catalytic or selective adsorption means can also be used to eliminate these impurities.

Packaged systems

Several complete packaged purification systems are available which take untreated compressed air and purify it to the highest standards. They are available for high and low pressure use and range from the replacement cartridge type to the automatic self regenerating type for continuous use.

Whatever system is used, it is fundamental to the safety of the user that the specified system shall be capable of providing quality air of a consistently high standard under varying environment conditions. Product integrity, quality assurance and verification are essential characteristics of any supplier of breathing air equipment. A system should be calculated on the basis of 180 litre/min (II m3/hr), based on an inlet pressure of7 bar and 20°C. For other pressures and temperatures, the purifier should be derated in accordance with Table 4. Units are available to serve up to 24 masks.

Compressed Air Transmission and Treatment-0273

Note: the corrected flow of the unit is obtained by multiplying the nominal flow by the two factors obtained from the table.

Related posts:

Pumping system hydraulic characteristics:Pump curves and Pump operating point.
Compressed Air Transmission and Treatment:Hollow fibre filter
Compressed Air Transmission and Treatment:Breathing apparatus standards
Particle degradation:Pneumatic conveying data and Experimental details
Gas–solid separation devices:Dust control and Particle degradation
High pressure:Single blow tank systems
Low pressure and vacuum:Air leakage
Pipeline scaling parameters:Pipeline bore and Empty line pressure drop
Hydraulic pumps:Maintenance practice
Control components in a hydraulic system:Servo valves
Fundamental Principles:fluId flow
Air Compressors, Air Treatment and Pressure Regulation:air receivers and compressor control
PROPERTIES OF PURE SUBSTANCES:PHASES OF A PURE SUBSTANCE
SUMMARY OF PROPERTIES OF PURE SUBSTANCES
THE SECOND LA W OF THERMODYNAMICS:INTRODUCTION TO THE SECOND LAW

Leave a comment

Your email address will not be published. Required fields are marked *