Linear actuators:Mounting arrangements and Cylinder dynamics.

Mounting arrangements

Cylinder mounting is determined by the application. Two basic types are shown in Figure 5.14. The clamp of Figure 5.14a requires a simple fixed mounting. The pusher of Figure 5.15b requires a cylinder mount which can pivot.

Actuators-0144

Figure 5.15 shows various mounting methods using these two basic types. The effects of side loads should be considered on non­ centreline mountings such as the foot mount. Swivel mounting obviously requires flexible pipes.

Cylinder dynamics

The cylinder in Figure 5.16a is used to lift a load of mass M. Assume it is retracted, and the top portion of the cylinder is pres­surised. The extending force is given by the expression:

image

To lift the load at all, F>Mg+f where M is the mass and f the static frictional force.

Actuators-0145

The response of this simple system is shown in Figure 5.16b. At time W the rod side of the cylinder is vented and pressure is applied to the other side of the piston. The pressure on both sides of the piston changes exponentially, with falling pressure P2 changing slower than inlet pressure P1, because of the larger volume. At time X, extension force P1A is larger than P2a, but movement does not  start until time Y when force, given by expression 5.6, exceeds  mass and frictional force.

The load now accelerates with acceleration given by Newton’s law:

image

Where Fa= P1A- P2a- Mg- f.

It should be remembered that Fa is not constant, because both P1 and P2 will be changing. Eventually the load will reach a steady velocity, at time Z. This velocity is determined by maximum input flow rate or maximum outlet flow rate (whichever is lowest). Outlet pressure P2 is determined by back pressure from the outlet line to tank or atmosphere, and inlet pressure is given by the expression:

image

The time from W toY, before the cylinder starts to move, is called the ‘dead time’ or ‘response time’. It is determined primarily by the decay of pressure on the outlet side, and can be reduced by de­ pressurising the outlet side in advance or (for pneumatic systems) by the use of quick exhaust valves (described in Chapter 4).

The acceleration is determined primarily by the inlet pressure and the area of the inlet side of the piston (term P1A in expression 5.6). The area, however, interacts with the dead time – a larger  area, say, gives increased acceleration but also increases cylinder volume and hence extends the time taken to vent fluid on the outlet side.

Actuators-0146

Related posts:

Benefits, drawbacks and operational issues:Power drive system integration
Variable speed drives:Variable speed drives for other AC motors
Applications on pneumatic:Contractors tools
Compressed Air Transmission and Treatment:Breathing apparatus standards
Pipelines and valves:Pipeline material,Hygiene and Hoses
THE COMPRESSOR:COMPRESSOR NOISE REDUCTION
Troubleshooting and material flow problems:Over feeding of pipeline
ROUBLESHOOTING HYDRAULIC SYSTEMS:ISOLATING PROBLEMS IN A HYDRAULIC CIRCUIT
Hydraulic cylinders:Cylinder mountings.
Process control valves and actuators:Flow control valves ,Actuators and Valve positioners.
Fundamental Principles:temperature measurement
Hydraulic and Pneumatic Accessories:Pneumatic Piping, Hoses and connections
THE SECOND LA W OF THERMODYNAMICS:THE CARNOT PRINCIPLES
ENTROPY
POWER AND REFRIGER A TION CYCLES:AIR-STANDARD ASSUMPTIONS

Leave a comment

Your email address will not be published. Required fields are marked *