Pressure measurement

Behavior of a fluid can generally be deduced from measurements of flow or pressure. A flow transducer or transmitter has to be plumbed, in line, into a pipe, whereas pressure transmitters can be added non-intrusively as tappings to the side of a pipe. The basic fault-finding tool in both pneumatic or hydraulic systems is therefore a pressure gauge. Often this is a simple gauge which can be plugged into various parts of the system via a flexible connection.

These test pressure gauges invariably measure gauge pressure with the simple Bourdon pressure gauge shown in Figure 1.13. This consists of a flat- tened C-shaped tube which is fixed at one end, shown in Figure 1.13a. When pressure is applied to the tube it tends to straighten, with the free end moving up and to the right. For low pressure ranges a spiral tube is used to increase the sensitivity.

This movement is converted to a circular pointer movement by a me- chanical quadrant and pinion. If an electrical output signal is required for remote indication, the pointer can be replaced by a potentiometer, as shown in Figure 1.13b.

Hydraulic and pneumatic systems tend to exhibit large pressure spikes as loads accelerate or decelerate (a typical example being shown in Figure 1.12c). These spikes can be irritating to the observer, can mislead, and in extreme cases could damage a pressure indicator. The response of a pressure sensor can be dampened by inclusion of a snubber restriction, as shown in Figure 1.13c.

Bourdon gauge-based transducers are generally robust but are low-accuracy (typically ± 2%) devices. As the limit of visual resolution of a pointer position is no better than ± 2% anyway, ruggedness of these transducers makes them ideal for plant-mounted monitoring.

Where more accurate pressure measurement is required, transducers based on the force balance principle of Figure 1.14 are generally used. This is essen- tially a differential pressure transducer, in which the low-pressure inlet (LP) is left open to atmosphere and the high-pressure (HP) inlet connects to the system. The signal given (HP − LP) is thus gauge pressure.

A pressure increase in the system deflects the pressure-sensitive diaphragm to the left. This movement is detected by the displacement transducer which, via a servo amplifier, leads to an increase in current in the balance coil.

Because the force from the balance coil always exactly balances the force arising from the pressure difference between LP and HP, current through the transducer is directly proportional to the differential pressure.

Remote indicating transducers are generally arranged with a remote power supply and the indicator and/or recorder connected into one line as in Figure 1.15 to give a two-wire system. A signal range of 4–20 mA is commonly used, with the 4 mA zero level providing a current supply for the transducer’s servo ampli- fier and also indicating circuit continuity (0 mA indicating an open circuit fault condition).

Fundamental Principles-0020

Fundamental Principles-0021

Incoming search terms:

Related posts:

Compressed Air Transmission and Treatment:Humidity control and Theory of coalescing filters
Moisture and condensation:Air processes and Condensation in reception hopper.
Erosive wear:Influence of variables and Theories proposed.
Operating problems:System related
Material property influences:Conveying modes and Dilute phase non-suspension flow.
FORCES IN LIQUIDS:TRANSMISSION OF FORCE THROUGH LIQUIDS.
Hydraulic fluids
CONTROL VALVES:Rotary Spool Four- Way Valves
Air Compressors, Air Treatment and Pressure Regulation:air treatment
Hydraulic and Pneumatic Accessories:Hydraulic Piping, Hosing and connections.
INTRODUCTION AND OVERVIE:PROBLEM-SOLVING TECHNIQUE
BASICCONCEPTS OF THE RMODYNAMICS:PROPERTIES OF A SYSTEM
ENTROPY:ENTROPY CHANGE OF LIQUIDS AND SOLIDS
SUMMARY OF HEAT EXCHANGERS
RADIATION HEAT TRANSFER:THE VIEW FACTOR

Leave a comment

Your email address will not be published. Required fields are marked *