Energy and Efficiency:The complete isothermal formula

The complete isothermal formula

The equation for compressible flow, which takes into account that the pressure at the end of a long pipe may be significantly smaller than that at the beginning, is:

Energy and Efficiency-0222

This is correct for any consistent set of units. In particular, in conformity with the standard nomenclature, it applies where L, D and A are expressed in metres, P in N/m 2 and w in kg/s.

This solution is developed on the basis of the following assumptions:

• Isothermal flow

• No mechanical work done on the system

• Steady flow

• The velocity is the average across the section

• The gas obeys perfect gas laws, ie the compressibility factor is unity

• Friction factor is constant

• The pipe is straight and level.

For gas flow it is permissible to add one further assumption:

• Forces due to acceleration of the flow can be neglected.

Equation [2] now becomes:

Energy and Efficiency-0223

It can be seen that this is equivalent to the incompressible Darcy equation if the pressure difference between the ends is small. It can also be seen that if the pressure drop is less than 10% of the inlet pressure and is based on the conditions at either inlet or outlet, the formula is accurate to about 5 %, which is satisfactory for most purposes. If the pressure drop is more than 10% and less than 40%, the formula can still be used provided the average value of p is used. Note that this procedure may involve iteration if the first guess of pressure drop proves to be inaccurate. For long pipelines, where the pressure drop is greater than 40%, two techniques can be used; one is to divide the pipe into shorter sections and then by a process of iteration solve for the complete pipe; the other is to use equation (2]. The latter procedure cannot take into account differences in the value of p along the length. If a significant pressure drop of this magnitude is found to occur in a normal compressed air layout, there is quite obviously a fault in the design of the system which should be remedied.

Equation [3] expressed in the usual units becomes

Energy and Efficiency-0224

Related posts:

Applied Pneumatics:Flow analysis for cylinders and valves
Compressed Air Transmission and Treatment:STERILE AIR AND GAS FILTERS
Moisture and condensation:Humidity and Specific humidity
Erosive wear:Hard materials and Particle concentration
Introduction to pneumatic conveying and the guide:Nomenclature
Material property influences:Material grade influences and Alumina.
Conveying capability:System capability
Maintenance and troubleshooting
Application notes: Speed control ,Actuator synchronisation.
Air treatment:Stages of air treatment,Filters,Air dryers and Lubricators.
Compressor types:Piston compressors,Screw compressors,Rotary compressors and Dynamic compressors.
SUMMARY OF INTRODUCTION AND OVERVIE
PROPERTIES OF PURE SUBSTANCES:INTERNAL ENERGY, ENTHALPY, AND SPECIFIC HEATS OF SOLIDS AND LIQUIDS
GAS MIXTURES AND PSYCHROMETRICS:DRY AND ATMOSPHERIC AIR
GAS MIXTURES AND PSYCHROMETRICS:DEW-POINT TEMPERATURE

Leave a comment

Your email address will not be published. Required fields are marked *