Compressed Air Transmission and Treatment:Inducted contaminants

Inducted contaminants

Industrial stationary compressors are normally installed in separate rooms away from factory contaminants, drawing in air from the outside atmosphere as in Figure 3. The level of dust concentration is likely to be of the order of I0-50 mg/m 3• It is standard practice to fit the compressor with an intake filter, having an efficiency of the order of 99.9%, based on the dust concentration present in the ambient air (see Tables 3 and 4). The intake filter can be expected to pass all particles smaller than 5 micron as well as a proportion of the larger sizes. It will also pass atmospheric water vapour and all gases, bacteria and viruses.

Compressed Air Transmission and Treatment-0257

Compressed Air Transmission and Treatment-0258Compressed Air Transmission and Treatment-0259

Types of intake filters

Intake filters (Figure 4) commonly used are:

• Paper filters- with renewable elements used on all types of compressors. Filtering efficiency is high (over 99%) with a typical pressure drop of 2.5 to 3.5 mbar if correctly sized. They are not recommended for use with reciprocating compressors

Compressed Air Transmission and Treatment-0260

unless a pulsation chamber is incorporated between the filter and the compressor intake. They are not suitable for handling air in excess of 80°C.

• Fabric filters – stronger than paper and generally cleanable by back flow of compressed air and sometimes by washing.

• Oil bath filters- which have a higher solid retention capability than the above, with a capacity for collecting impurities equal to the mass of the oil. They are not suitable for use on piston compressors unloaded by closing the air inlet valve, unless installed with a bypass or check valve to prevent oil being blown back out of the filter with reversed air flow.

• Labyrinth type oil wetted filters- mostly used on small compressors inducting relatively clean air. They require periodic cleaning.

• Inertial filters – reverse flow or cyclonic, suitable for coarse filtering of large volumes of air. They are normally used as pre-filters in conjunction with one of the other types mentioned above.

The intake filter is normally specified by the compressor manufacturer based on the operating conditions.

Related posts:

Variable speed drives:Variable speed drives for other AC motors
System and process requirements:Introduction to variable speed concept
Compressed Air Transmission and Treatment:AIR DRYERS
Compressed Air Transmission and Treatment:STERILE AIR AND GAS FILTERS
Particle degradation:Test rigs and data sources
Operating problems:Rotary valves and Flow control
MAINTENANCE OF HYDRAULIC SYSTEMS:ROOT CAUSE FAILURE ANALYSIS
BASIC HYDRAULICS:STATES OF MATTER.
Control components in a hydraulic system:Pressure and temperature switches.
Types of control valve:Poppet valves,Spool valves and Rotary valves.
Sequencing Applications:Pressure-controlled sequences
Safety, Fault-Finding and Maintenance:safety
INTRODUCTION AND OVERVIE:THERMODYNAMICS
ENTROPY:ENTROPY CHANGE OF PURE SUBSTANCES
POWER AND REFRIGER A TION CYCLES:DEVIATION OF ACTUAL VAPOR POWER CYCLES FROM IDEALIZED ONES

Leave a comment

Your email address will not be published. Required fields are marked *