Benefits, drawbacks and operational issues:Resonant vibrations in vertical pumps

Resonant vibrations in vertical pumps

Variable speed vertical pumps are more likely than horizontal machines to exhibit operational zones of excessive vibration, because their lower natural frequencies are more likely to coincide with running speeds. Some specific guidance is therefore provided in this Chapter.

Small, vertical close-coupled and multistage pumps do not normally show this type of problem.

Most manufacturers of large vertical pumps and motors have in-house technology to determine the natural reed frequency (NRF) and will do this job by job on engineered vertical pump sets.

It is normal practice to design the driver support (discharge head) of vertical pumps, such that the NRF of the pump/motor unit has a separation margin of 20% above the maximum operating r/min, or 20% below the mini­ mum operating r/min. The motor NRF is needed to make this calculation. If this criterion is not satisfied it may be possible to select a pump with a different synchronous full speed; as an example changing from six pole to four pole or six pole to eight pole, to achieve the desired non-resonance band of operation. The specifying engineer should consult with the pump manufacturer prior to specifying motor synchronous speed and the pump speed ranges, when the vertical pump is driven by a variable speed driver.

Another way of avoiding the pump running at the NRF is to lock out the problem speed zone of operation on the variable frequency drive (VFD) control. The pump may have different NRFs in the x andy directions, so it is necessary to avoid a band of speeds as shown in Figure 11.1. This may limit the pump’s useful range of operation: therefore, it is usually preferable if possible to change the pump/motor structural stiffness to move the resonance band away from the desired operating zone.

The influence of the foundation stiffness on the NRF must be considered. It is desirable to have a foundation that will create less than 5% of the total deflection of the pump/driver structural elements. Typically a reinforced concrete foundation will achieve this.

If the NRF is close to the maximum range of operating speed (Figure 11.2), the unit usually may be stiffened. However, there is a limit to the pump manufacturer’s ability to stiffen the unit’s structure. Procuring a stiffer vertical motor may not be feasible. However, by providing a stiffer motor support (fabricated discharge head) it may be possible to raise the pump’s NRF above maximum operating speed.

VARIABLE SPEED PUMPING-0776

If the NRF is close to the minimum range of operating speed (Figure 11.3), the unit may be made more flexible. This will lower the natural frequency below the operating range. During start-up and shutdown, the unit will pass through its natural frequency and vibration may occur. However, this vibration should not be damaging due to its very short duration of time.

Related posts:

Case studies:VSD installation and commissioning Borehole pump
Selection process - new systems:Flow charts
Compressed Air Transmission and Treatment:SYSTEM MAINTENANCE
Pipelines and valves:Steps
Multiple use systems:Multiple material handling and Air supply control.
Operating problems:Rotary valves and Flow control
Review of pneumatic conveying systems:System types,Open systems and Positive pressure systems.
Design procedures:The use of equations in system design and Logic diagram for system design.
Process control valves and actuators:Flow control valves ,Actuators and Valve positioners.
Hydraulic coolers and heat exchangers.
Check valves:Pilot-operated check valves and Restriction check valves.
Process Control Pneumatics:the flapper-nozzle
PROPERTIES OF PURE SUBSTANCES:COMPRESSIBILITY FACTOR—A MEASURE OF DEVIATION FROM IDEAL-GAS...
RADIATION HEAT TRANSFER: BLACK SURFACES
INTRODUCTION TO FLUID MECHANICS:VAPOR PRESSURE AND CAVITATION

Leave a comment

Your email address will not be published. Required fields are marked *