Compressed Air Transmission and Treatment:Water vapour

Water vapour

Ambient air always contains water vapour. After it leaves the compressor, it is fully saturated with water vapour, the actual amount present being directly proportional to the temperature and inversely proportional to the pressure, see Table 5. The liquid water is best removed when the temperature of the air is lowest and the pressure is highest,

Compressed Air Transmission and Treatment-0261

Example: I m3 of air at atmospheric conditions fully saturated at 20°C contains 17.4 g of water vapour. When compressed to 6.3 bar and 50°C it can only retain 11.2 gas vapour, therefore 6.2 g ( 17.4 – 11.2) is released as liquid water. If cooled down to 25°C a further quantity of 7.93 g ( 11.2- 3.27) of water will condense out.

ie immediately after the compressor and its aftercooler. Standard practice is to follow the compressor element with an after cooler of sufficient capacity to reduce the temperature to within 10°C of the temperature of the cooling water or air. In the former case, approximately 20 litres of water will be required for every 2.5 m3 of free air being cooled. Further cooling is possible if a reasonably large receiver is fitted.

Refer to the chapter on Air Receivers to assess the proper volume. It is often quoted that the size of the receiver should be approximately equal to 30 times the rated free air deli very of the compressor, for 7 bar applications. A receiver should incorporate a condensate drain, preferably of an automatic type.

Further cooling is likely to occur in the distribution main, so these should be laid out with a pitch in the direction of flow so that gravity and air flow will carry the water to drain legs, located at appropriate intervals. These also should be fitted with automatic drain valves to prevent them being flooded. Down loops in the distribution main should be avoided where possible, but if this cannot be avoided, they mustincorporatedrain legs at the bottom of the down loop. All take-off points from the distribution main should be located at the top of the main to prevent water getting into the take-off line.

Related posts:

Case studies:Benefits given by the use of environmental temperature control using reciprocating PD p...
Case studies:VSD installation and commissioning Borehole pump
Particle degradation:Test rigs and data sources
Troubleshooting and material flow problems:Over feeding of pipeline
Coarse material:Dilute phase conveying of magnesium sulphate
Material property influences:Fly ash
Conveying characteristics:The determination of conveying characteristics
MAINTENANCE OF HYDRAULIC SYSTEMS:MEASURING SUCCESS.
FORCES IN LIQUIDS:STREAMLINE AND TURBULENT FLOW.
Introduction to hydraulics:Introduction and background
Hydraulic and Pneumatic Accessories:Hydraulic coolers and Heat exchangers
Process Control Pneumatics:the air relay and the force balance Principle
PROPERTIES OF PURE SUBSTANCES:PHASE-CHANGE PROCESSES OF PURE SUBSTANCES
PROPERTIES OF PURE SUBSTANCES:THE IDEAL-GAS EQUATION OF STATE
INTRODUCTION TO FLUID MECHANICS:VAPOR PRESSURE AND CAVITATION

Leave a comment

Your email address will not be published. Required fields are marked *