Case studies:Benefits given by the use of environmental temperature control using reciprocating PD pumps driven by VSD

Case study 8: Benefits given by the use of environmental temperature control using reciprocating PD pumps driven by VSD

Case study summary

Reciprocating positive displacement pumps were used for the application of temperature control in a paper mill, where the requirement was for a variable flow rate of demineralised water.

To cool high ambient temperatures for a number of applications, the technique of atomizing water into fine droplets was employed.

The performance required was from 0.1 1/min to 3.0 1/min at pressures up to 80 bar. The duty involved cooling the environment surrounding the paper forming process to prevent premature drying.

Installed details

The PD pumps chosen were powered by an electric motor controlled by an integrated electronic variable frequency drive.

The water, vaporized at the nozzles, lowers the temperature by absorbing its latent heat of vaporization.

By linking a temperature sensor via a programmable logic controller (PLC) to the variable frequency drive it is possible to control the volume of water discharged, and hence the resulting temperature.

VARIABLE SPEED PUMPING-0783

General benefits seen by the use of VSD PD pumps
The energy that was wasted and returned to the water source was dissipated mainly as heat as it is passed through the regulator . By not pumping at full output this energy wastage is reduced. The alternative would be to run the pump at full flow and use a pressure regulating valve opening to control the feed to the nozzles. The excess flow would then have to be diverted back to source via a pressure regulator, which would require a much larger source tank to ensure that the water temperature rise was acceptable.

As well as the long-term continual energy savings seen by using a VSD pump, rather than wasting energy and dissipating pressure across a valve, the response from a VFD allows improved system controllability.

Related posts:

Compressed Air Transmission and Treatment:Compressed air distribution
Particle degradation:Pneumatic conveying data and Experimental details
Health and safety:Conveying operations
Particle degradation:Operating problems and Filtration problems
Operating problems:System related
Coarse material:Dilute phase conveying of magnesium sulphate
ROUBLESHOOTING HYDRAULIC SYSTEMS:ISOLATING PROBLEMS IN A HYDRAULIC CIRCUIT
Hydraulic fluids:Foam-resistant fluids
Linear actuators:Construction.
Air Compressors, Air Treatment and Pressure Regulation:Pressure regulation
PROPERTIES OF PURE SUBSTANCES:INTERNAL ENERGY, ENTHALPY, AND SPECIFIC HEATS OF SOLIDS AND LIQUIDS
THE SECOND LA W OF THERMODYNAMICS:PERPETUAL-MOTION MACHINES
RADIATION HEAT TRANSFER:RADIATION SHIELDS AND THE RADIATION EFFECTS
HEAT EXCHANGERS:THE LOG MEAN TEMPERATURE DIFFERENCE METHOD
INTRODUCTION TO FLUID MECHANICS:VAPOR PRESSURE AND CAVITATION

Leave a comment

Your email address will not be published. Required fields are marked *