Starting and generating systems:Voltage regulation

Voltage regulation

Most alternator-based charging circuits employ voltage regulation (as opposed to voltage and current regulation). The regulator can be external to the alternator or integral with it. External regulators can be mechanical or solid state.

External regulators

Figure 11-39 is a schematic of a typical mechanical voltage regulator. The voltage-sensing winding is in parallel with the output and drives NC (normally closed) contacts. As the generator comes up to speed, voltage increases until the winding develops a strong enough field to open the contacts. Rotor output then passes through dropping resistor RF.

Depending on the make and model, voltage adjustment is accomplished by bending the stationary contact, moving the hinges in elongated mounting holes, or by screw (Fig. 11-40). In theory, the correct point gap should correspond with an output voltage of approximately 15V at 68°F or 28V for 24V systems. In practice, better results are had by measuring alternator output voltage at the battery terminals. Assuming that specifications are available, core and yoke gap adjustments also can be made.

Clean oxidized contacts with a riffle file or a diamond-faced abrasive strip. Do not use sandpaper or emery cloth. Inspect the dropping resistor (often found on the underside of the unit), springs, and contact tips for evidence of overheating. Check the regulator ground connection.

Starting and generating systems-0450

Starting and generating systems-0451

Before discarding a defective regulator, attempt to discover why it failed. Burnt points or heat-discolored springs mean high resistance in the charging circuit or a bad regulator ground.

Related posts:

Circuit-Level Transient Suppression:Protecting High-Voltage Supplies.
Facility Wiring and Transient Protection:Facility Wiring.
The power system:Transmission.
Measurements and instrumentation:Pressure.
Low-Voltage Switchgear and Circuit Breakers:Air Disconnect Switches, Fuses, and Insulators
Testing and Commissioning of Protective Relays and Instrument Transformers:Types of Relay Tests
Thermal Loading of Several Multilevel Converter Topologies for 10 MW Wind Turbines Under Low Voltage...
BIOMASS-BASED POWER GENERATION:BIOMASS GASIFICATION
POWER FROM WASTE:WASTE PLANT EMISSIONS
Thermal Loading of Several Multilevel Converter Topologies for 10 MW Wind Turbines Under Low Voltage...
The Current Situation and Perspectives on the Use of Wind Energy for Electricity Generation:Romania
The Current Situation and Perspectives on the Use of Biomass in the Generation of Electricity:Advant...
Taxonomy of Uncertainty Modeling Techniques in Renewable Energy System Studies:Probabilistic Approac...
Adopting the IEC Common Information Model to Enable Smart Grid Interoperability and Knowledge Repres...
Adopting the IEC Common Information Model to Enable Smart Grid Interoperability and Knowledge Repres...

Leave a comment

Your email address will not be published. Required fields are marked *